Contract Laboratory .com analytical chemistry, pharmaceutical, toxicology, clinical research, pharmacology, bioanalytical, sterility, pyrogen, medical devices, cosmetics, food, nutritional, preclinical, biomechanical, biotechnology, pharmacokinetic testing laboratories for all your US FDA required GMP, GLP, GCP QC, NF USP, BP, ISO, ANSI, AAMI, AOAC, BAM,  raw material, in-process, and finished product,  testing.
Contract Laboratory .com
Find FDA GMP, GLP, GCP, ISO, CLIA, UKAS, AAALAC, A2LA, and Other Find FDA Laboratories for all your FDALaboratory Testing and Scientific Research!
FDA Inspection . com
FDA Directories
FDA Inspection
Cosmetic Inspections
 
 

 

equations, conversion factors, formulas, constants

 
constants
name constant source
atomic mass constant 1.660 538 73 x 10-27 kg NIST Fundamental Physical Constants
Avogadro constant 6.022 141 99 x 1023 mol-1 NIST Fundamental Physical Constants
electron volt 1.602 176 462 x 10-19 J NIST Fundamental Physical Constants
elementary charge 1.602 176 462 x 10-19 C NIST Fundamental Physical Constants
Faraday constant 96 485.3415 C mol-1 NIST Fundamental Physical Constants
Molar Gas constant 8.314 472 J mol-1 K-1 NIST Fundamental Physical Constants
Newtonian constant of gravitation 6.673 x 10-11 m3 kg-1 s-2 NIST Fundamental Physical Constants
Planck constant 6.626 068 76 x 10-34 J s NIST Fundamental Physical Constants
Proton Mass 1.672 621 58 x 10-27 kg NIST Fundamental Physical Constants
Rydberg Constant 10 973 731.568 549 m-1 NIST Fundamental Physical Constants
Speed of Light in Vaccum 299 792 458 m s-1 NIST Fundamental Physical Constants
Fine-Structure constant 7.297 352 533 x 10-3 NIST Fundamental Physical Constants
Magnetic constant 4pi x 10-7 = 12.566 370 614... x 10-7 N A-2 NIST Fundamental Physical Constants
conversion factors
name conversion factor source
dipole moment 1 debye = 3.335 64 × 10-30 C·m NIST Wavenumber Conversion Tables
wavenumber 1 cm-1 = 29 979.2458 MHz NIST Wavenumber Conversion Tables
pressure 1 atm = 101 325. Pa (pascal) NIST Wavenumber Conversion Tables
pressure 1 torr = 133.322 Pa NIST Wavenumber Conversion Tables
absorption intensity 1 cm-2 atm-1 at 296 K = 4.033 × 10-20 cm/molecule NIST Wavenumber Conversion Tables
equations
name equation source
Peak intensity of a Lorentzian line

% transmission = 100 exp(-0.7789 × 1014 Slp/L),

where S is the intensity given in the tables, L is the Lorentzian half-width at half height, l is the pathlength in cm, and p is the pressure in Pa

NIST Wavenumber Conversion Tables
Peak intensity of a Doppler shaped line

% transmission = 100 exp(-1.1494 × 1014 Slp/D)

where S is the intensity given in the tables, l is the pathlength in cm, and p is the pressure in Pa

NIST Wavenumber Conversion Tables
Doppler half-width at half intensity, D

D = 3.581 × 10-7 (T/M )1/2

where is the frequency in the same units as D , T is the temperature in kelvin, and M is the mass of the molecule in atomic mass units.

NIST Wavenumber Conversion Tables
Boltzmann factor

Ni = Nj exp(-1.439 Eij / T)

where Ni is the population of the ith level and Nj is the population of the jth level with energy difference in cm-1 of Eij at a temperature of T kelvin.

NIST Wavenumber Conversion Tables
   
   
   
   
   
 